Inspection is how the system stays in service after install day.

The Inspection and Recertification program includes:

  • Recertification of existing engineered fall protection systems
  • Inspection of existing engineered fall protection systems including taking detailed pictures, providing accurate descriptions of the system and providing any insight on what needs attention.
  • Operational training on how to use the system for new employees
  • PPE and SRL inspection and recertification
  • Emergency repair and maintenance
  • Dedicated service support team that can provide information on your systems and equipment readily available.

If Tritech designed and installed the system, this is a continuation of that work, not a separate product. See our fall protection services and Our Process.

A Tritech inspection tag on an installed fall protection system, with the installation date and spaces for annual inspection dates.

Canadian CSA Regulations

12.3 Annual or periodic inspection
Employers shall ensure a competent person performs an annual documented inspection of all fall protection equipment and systems. More frequent inspections might be required if  specified by the manufacturer or design engineer. The intervals specified in Table 5 for each item shall apply in the absence of such recommendations. Equipment used under harsh  conditions or higher frequency of use shall be inspected more frequently than specified in Table 5. 

U.S. OSHA and ANSI (US) Regulations

“OSHA General Duty Clause”
Section 5a1 of the OSH Act says:

Each employer shall furnish to each of his employees employment and a place of employment which are free from recognized hazards that are causing or are likely to cause death or serious physical harm to his employees.

ANSI Z359

  • ANSI/ASSP Z359.2-2023 Minimum Requirements for a Comprehensive Managed Fall Protection Program
  • ANSI/ASSP Z359.6-2026 Specifications and Design Requirements for Active Fall Protection Systems All Manufacturer Requirements

5 Year Engineering Design Review and Recertification requirements of ANSI:

  • ANSI/ASSP Z359.6-2026
  • 9.1.2 The certification documentation shall state the frequency that the system shall be recertified by a qualified person. This frequency shall not exceed 5 years.
  • 9.2 Recertification of Active Fall Protection Systems
  • 9.2.1 Active fall protection systems shall be thoroughly reviewed by a qualified person at the frequency specified in 9.1.2.

Portal login is provided to all customers participating in the Tritech service program so they can review past inspections, photos and all documented, PPE and systems.

Schedule an inspection

This field is for validation purposes and should be left unchanged.
Drop files here or
Accepted file types: pdf, dwg, dxf, jpg, jpeg, png, Max. file size: 20 MB, Max. files: 5.
    Optional. Engineering drawings, site plans or photos — up to 5 files, 20 MB each (PDF, DWG, DXF, JPG or PNG).