Brochure

Rooftop Guardrail Systems Brochure

How Tritech engineers rooftop guardrail for membrane, metal, parapet and temporary roofs: four configurations, edge-distance zones and site engineering.

PDF · 4 pages · 2.2 MB · Rev. 2026

Download the PDF Work email required, once

What’s inside

  • Three work zones defined by distance from the roof edge, and what each allows
  • Freestanding counterbalanced guardrail for membrane, built-up and concrete roofs
  • Standing-seam guardrail for metal roofs up to a 45° pitch
  • Parapet and wall-mounted rail with no counterweights on the roof
  • Portable guardrail for contractors and short-term projects
  • The wind, layout and anchor calculations delivered with every run

The edge is where the exposure is, and equipment tends to sit near it

Most roof trips are to service equipment, and much of that equipment is installed close to the edge. This brochure is written for facility managers, safety leads and building owners who have to decide how the people on their roofs are protected. It breaks the roof into three zones by distance from the edge (inside 6 ft, 6 to 15 ft, and beyond 15 ft) and explains which controls are acceptable in each, including when a designated area with a physical warning line can be used and when it cannot.

Guardrail is the one control that asks nothing of the worker

Harnesses must be worn, inspected and anchored, and designated areas must be enforced. A guardrail simply stays in place. The brochure covers four Tritech configurations built from one modular, galvanized component system:

  • Freestanding counterbalanced guardrail that sits on the membrane with no penetrations
  • Metal roof guardrail clamped to the standing seam or profile
  • Parapet and wall-mounted rail for tight roofs
  • Portable guardrail that moves with the work

It also shows how a modular run is routed around pipes, ductwork, curbs and HVAC units without leaving a gap.

A counterbalanced guardrail is a structure and is engineered as one

Each base acts as a lever through the cantilever arm, so arm length, base count and spacing decide whether the rail holds under load and wind. Tritech engineers size every run for the building: wind load by basic wind velocity, exposure category and roof height; layout drawings for post spacing, arms, corners and obstructions; and anchor loads for parapet-mounted runs. Tritech has engineered, supplied, installed and certified fall protection systems across North America since 1993, and the same crews that design a system install it.

Key specs

Top-rail height42 in. (±3 in.)
Top-rail load200 lb at any point, outward or downward
Counterbalance base weight30 lb, molded from 100% recycled PVC
Roof penetrations0 (no drilling, welding or hot work)
Counterbalance arm lengths91½ in. full-length, 55 in. compact
Metal roof pitchUp to 45°
Parapet post spacing8 ft centers
Warning line height (designated areas)34 to 39 in.
FinishHot-dip galvanized; powder-coated RAL colors available

Questions about this brochure

Does a counterbalanced guardrail need to be fastened to the roof?

No. The freestanding system uses 30 lb recycled-PVC bases on cantilever arms, so load on the top rail is resisted by the weight of the bases rather than fasteners. Nothing is drilled, welded or sealed into the membrane. Tritech engineers set the arm length, base count and spacing for each site so the rail holds under its rated load and under wind.

Can a painted line mark a safe work area on a roof?

No. The brochure explains that a designated area needs a physical warning line between the worker and the edge, set 34 to 39 in. high, so it stays visible under snow, dust, debris or equipment. Where roof work is routine rather than infrequent and short, a designated area is not an option and guardrail is the practical answer.

What guardrail works when there is no room for counterweights?

Parapet and wall-mounted guardrail fixes the rail to the parapet or wall through a wall flange, with posts at 8 ft centers. It uses no counterweights and takes no roof area, and it transitions to a freestanding run where the wall ends. It suits roofs where every square foot of surface needs to stay usable.

Used on

Where this applies

Have a site in mind?

Tell us about the hazard. We’ll tell you what we’d install, how long it takes and what it costs.

Speak with an Expert

Brochure

Rooftop Guardrail Systems Brochure

Enter your name and work email and the PDF downloads straight away. We’ll email you the link too. You’ll only be asked once.

We’ll email the PDF. No spam, no sequences. Privacy policy.